Pressure Controller-S/D Series

Description:
1.For use with fluorinated refrigerants as well as with air and liquid;(Allowable fluid temp.:-45ºC~+120ºC);
2.Various contact functions available,with SPDT contact mechanism;
3.Renovated micro-swith structure ensures the reliable switch function;
4.Manual-controlled and no use of other instruments to have a function test;
5.Flexible mounting plate suits various kinds of application;
6.1/4,G1/4,capillary or special connetion can be available and please inform us when placing order.


Coolsour Differential Low Air Compressor Automatic Pressure Control Switch
 
Type Pressure   Pressure range  (Mpa)   Differential range  (Mpa)   Factory Setting   (Mpa) Max.Bellows Pressure (Mpa)
Min. Max. Min. Max. OFF ON
S103X Low -0.06 0.3 0.035 0.2 0.05 0.15 1.65
S106X Low -0.06 0.6 0.06 0.4 0.2 0.3 1.65
S110X Low 0.1 1 0.1 0.3 0.4 0.6 1.65
S120X High 0.5 2 0.2 0.5 1.5 1.2 4
D306X Dual L-H Low side -0.06 0.6 0.06 0.4 0.2 0.3 1.65
High side 0.8 3 Fixed 0.4 Fixed 0.4 2 1.6 4
D606X Dual L-H Low side -0.06 0.6 0.06 0.4 0.2 0.3 1.65
High side 0.8 3 Fixed 0.4 Fixed 0.4 2 1.6 4
D306XM Dual L-H Low side -0.06 0.6 0.06 0.4 0.2 0.3 1.65
High side 0.8 3 pressure Rise-auto reset pressure Fall-manual reset 2 Manual Reset 4
D606XM Dual L-H Low side -0.06 0.6 0.06 0.4 0.2 0.3 1.65
High side 0.8 3 pressure Rise-auto reset pressure Fall-manual reset 2 Manual Reset 4
D606XMM Dual L-H Low side -0.06 0.6 pressure Rise-auto reset pressure Fall-manual reset 0.2 Manual Reset 1.65
High side 0.8 3 pressure Rise-auto reset pressure Fall-manual reset 2 Manual Reset 4

Pressure Controller-HLP Series

Description:
1.For use with fluorinated refrigerants as well as with air and liquid;(Allowable fluid temp.:-45ºC~+120ºC) 
2.Various contact functions available,with SPDT contact mechanism;
3.Renovated micro-swith structure ensures the reliable switch function;
4.Manual-controlled and no use of other instruments to have a function test;
5.Flexible mounting plate suits various kinds of application;
6.1/4,G1/4,capillary or special connetion can be available and please inform us when placing order.
Type Pressure   Pressure range  (Bar)   Differential range  (Mpa)   Factory Setting   (Mpa) Max.Bellows Pressure (Mpa)
Min. Max. Min. Max. OFF ON
HLP502 Low 0.25 1.5 0.2 1 1 0.5 16.5
HLP503 Low -0.7 3 0.5 1.5 2 1
HLP506 Low -0.7 6 0.5 3 3 2
HLP506M Low -0.7 6 Reset differential≤1 3 manual reset
HLP110 Low 1 10 1 3 6 5
HLP516 High 5 16 1 4 10 8 35
HLP520 High 5 24 2 5 16 13
HLP530D High 5 30 5 10 20 15
HLP530 High 8 30 Fixed 3-5 20 15
HLP530M High 8 30 Reset differential≥4 20 manual reset
HLP830 Dual L-H Low side -0.7 6 0.6 4 3 2 16.5
High side 8 30 Fixed 3-5 20 15 35
HLP830HM Dual L-H Low side -0.7 6 0.6 4 3 2 16.5
High side 8 30 Reset differential≥4 20 manual reset 35
HLP830HLM Dual L-H Low side -0.7 6 Reset differential≤1 3 manual reset 16.5
High side 8 30 Reset differential≥4 20 manual reset 35

Pressure Controller - P Series

Description:
1.Pressure contorl is used to protect refrigeration or airconditioning equipment from breathing pressure higheror exhausting lower in system of refrigeration compressor;
2.Pressure contorl is also used in the start & stop of the refrigeration compressors and air-cooled condenser fans;
3.With SPDT contact mechanism, allowable fluid Temp.:-10ºC~+110ºC;
4.Manual-control and no use of other instruments to have a function tests.
Model Pressure  Low Pressure(LP) High Pressure(HP) Reset Contact System
1/4" Flare 1/4" Solder Adjust Range Differential 
Pressure
Adjust Range Differential 
Pressure
Low Pressure
(LP)
High Pressure
(HP)
(bar) (bar) (bar) (bar)
PL1A PL1AS Low -0.2 → 7.5 0.7 → 4.0     Auto   SPDT
PL1M PL1MS Low -0.9 → 7.0 Fixed 0.7     Manual  
PL2A PL2AS Low -0.2 → 5.0 0.4 → 1.5     Auto  
PH5A PH5AS High     8 → 32 1.8 →6.0   Auto
PH5M PH5MS High     8 → 32 Fixed 3   Manual
PD15AA PD15AAS Dual -0.2 → 7.5 0.7 → 4.0 8 → 32 Fixed 4 Auto Auto SPDT+Low Signal
PD15AM PD15AMS Dual -0.2 → 7.5 0.7 → 4.0 8 → 32 Fixed 4 Auto Manual
PD15MM PD15MMS Dual -0.9 → 7.0 Fixed 0.7 8 → 32 Fixed 4 Manual Manual
PD15AAD PD15AADS Dual -0.2 → 7.5 0.7 → 4.0 8 → 32 Fixed 4 Auto Auto SPDT+Low& high Signal
PD15AMD PD15AMDS Dual -0.2 → 7.5 0.7 → 4.0 8 → 32 Fixed 4 Auto Manual
PL35A PL35AS Low  -0.2 → 7.5 0.7 → 4.0     Auto   SPDT
PL36A PL36AS Low  2 → 14 0.7 → 4.0     Auto  
PH38A PH38AS High     8 → 32 1.8 →6.0   Auto

Differential Pressure Switch

Description:
1.For use with fluorinated refrigerants as well as with air and liquid;(Allowable fluid temp.:-45ºC~+120ºC) 
2.Differential pressure of the pressure control is asdjustalbe;
3.Novel micro-switch ensures reliable switching;
4.Mounting bracket is suitable for different occasions;
5.It can be used  as protective devices for maintaining oil pressure of compressor for air-conditioning purpose
6.Two pattern: with or without time delay, delay time 60,90,120 seconds can be available;
7.1/4,G1/4,capillary or special connetion can be available and please inform us when order.
Type   Adjust range   ( bar) Factory setting differential     ( bar) Reset time(sec.) Max bellows Pressure
 ( bar)
HLD1.5C 0.3~1.5 0.3 without 17
HLD2C 0.3~2 0.5 without 17
HLD4C 0.5~4 1 without 17
HLD4H 2~4 2 without 33
HLD6H 2~6 2 without 33
HLD2TC 0.3~2 0.5 60,90,120 17
HLD4TC 0.5~4 1 60,90,120 17
HLD4TH 2~4 2 60,90,120 33
HLD6TH 2~6 2 60,90,120 33
  Pressure Controller-S/D Series

Description:
1.For use with fluorinated refrigerants as well as with air and liquid;(Allowable fluid temp.:-45ºC~+120ºC);
2.Various contact functions available,with SPDT contact mechanism;
3.Renovated micro-swith structure ensures the reliable switch function;
4.Manual-controlled and no use of other instruments to have a function test;
5.Flexible mounting plate suits various kinds of application;
6.1/4,G1/4,capillary or special connetion can be available and please inform us when placing order.


Coolsour Differential Low Air Compressor Automatic Pressure Control Switch
 
Type Pressure   Pressure range  (Mpa)   Differential range  (Mpa)   Factory Setting   (Mpa) Max.Bellows Pressure (Mpa)
Min. Max. Min. Max. OFF ON
S103X Low -0.06 0.3 0.035 0.2 0.05 0.15 1.65
S106X Low -0.06 0.6 0.06 0.4 0.2 0.3 1.65
S110X Low 0.1 1 0.1 0.3 0.4 0.6 1.65
S120X High 0.5 2 0.2 0.5 1.5 1.2 4
D306X Dual L-H Low side -0.06 0.6 0.06 0.4 0.2 0.3 1.65
High side 0.8 3 Fixed 0.4 Fixed 0.4 2 1.6 4
D606X Dual L-H Low side -0.06 0.6 0.06 0.4 0.2 0.3 1.65
High side 0.8 3 Fixed 0.4 Fixed 0.4 2 1.6 4
D306XM Dual L-H Low side -0.06 0.6 0.06 0.4 0.2 0.3 1.65
High side 0.8 3 pressure Rise-auto reset pressure Fall-manual reset 2 Manual Reset 4
D606XM Dual L-H Low side -0.06 0.6 0.06 0.4 0.2 0.3 1.65
High side 0.8 3 pressure Rise-auto reset pressure Fall-manual reset 2 Manual Reset 4
D606XMM Dual L-H Low side -0.06 0.6 pressure Rise-auto reset pressure Fall-manual reset 0.2 Manual Reset 1.65
High side 0.8 3 pressure Rise-auto reset pressure Fall-manual reset 2 Manual Reset 4

Pressure Controller-HLP Series

Description:
1.For use with fluorinated refrigerants as well as with air and liquid;(Allowable fluid temp.:-45ºC~+120ºC) 
2.Various contact functions available,with SPDT contact mechanism;
3.Renovated micro-swith structure ensures the reliable switch function;
4.Manual-controlled and no use of other instruments to have a function test;
5.Flexible mounting plate suits various kinds of application;
6.1/4,G1/4,capillary or special connetion can be available and please inform us when placing order.
Type Pressure   Pressure range  (Bar)   Differential range  (Mpa)   Factory Setting   (Mpa) Max.Bellows Pressure (Mpa)
Min. Max. Min. Max. OFF ON
HLP502 Low 0.25 1.5 0.2 1 1 0.5 16.5
HLP503 Low -0.7 3 0.5 1.5 2 1
HLP506 Low -0.7 6 0.5 3 3 2
HLP506M Low -0.7 6 Reset differential≤1 3 manual reset
HLP110 Low 1 10 1 3 6 5
HLP516 High 5 16 1 4 10 8 35
HLP520 High 5 24 2 5 16 13
HLP530D High 5 30 5 10 20 15
HLP530 High 8 30 Fixed 3-5 20 15
HLP530M High 8 30 Reset differential≥4 20 manual reset
HLP830 Dual L-H Low side -0.7 6 0.6 4 3 2 16.5
High side 8 30 Fixed 3-5 20 15 35
HLP830HM Dual L-H Low side -0.7 6 0.6 4 3 2 16.5
High side 8 30 Reset differential≥4 20 manual reset 35
HLP830HLM Dual L-H Low side -0.7 6 Reset differential≤1 3 manual reset 16.5
High side 8 30 Reset differential≥4 20 manual reset 35

Pressure Controller - P Series

Description:
1.Pressure contorl is used to protect refrigeration or airconditioning equipment from breathing pressure higheror exhausting lower in system of refrigeration compressor;
2.Pressure contorl is also used in the start & stop of the refrigeration compressors and air-cooled condenser fans;
3.With SPDT contact mechanism, allowable fluid Temp.:-10ºC~+110ºC;
4.Manual-control and no use of other instruments to have a function tests.
Model Pressure  Low Pressure(LP) High Pressure(HP) Reset Contact System
1/4" Flare 1/4" Solder Adjust Range Differential 
Pressure
Adjust Range Differential 
Pressure
Low Pressure
(LP)
High Pressure
(HP)
(bar) (bar) (bar) (bar)
PL1A PL1AS Low -0.2 → 7.5 0.7 → 4.0     Auto   SPDT
PL1M PL1MS Low -0.9 → 7.0 Fixed 0.7     Manual  
PL2A PL2AS Low -0.2 → 5.0 0.4 → 1.5     Auto  
PH5A PH5AS High     8 → 32 1.8 →6.0   Auto